F1206B0R25FW/STR [KYOCERA AVX]
Electric Fuse;型号: | F1206B0R25FW/STR |
厂家: | KYOCERA AVX |
描述: | Electric Fuse 电路保护 |
文件: | 总38页 (文件大小:700K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
A KYOCERA GROUP COMPANY
AVX
Accu-Guard Series
SMD Thin-Film Fuse
Accu-Guard®
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
How To Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Accu-Guard® II,
Type F0402G Low Current Miniature 0402 Size Thin-Film Fuses . . . . . . . . . .3
Accu-Guard® II,
Types F0402E, F0603E, F0603C, F0805B, F1206B and F0612D . . . . . . . . . . . .7
Accu-Guard®, Type 1206A* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Quality and Reliability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Handling and Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
How To Choose The Correct Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
*Not recommended for new designs, please consult factory.
NOTICE: Specifications are subject to change without notice. Contact your nearest AVX Sales Office for the latest specifications. All statements, information and data given
herein are believed to be accurate and reliable, but are presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements
or suggestions concerning possible use of our products are made without representation or warranty that any such use is free of patent infringement and are not
recommendations to infringe any patent. The user should not assume that all safety measures are indicated or that other measures may not be required. Specifications are
typical and may not apply to all applications.
© AVX Corporation
Accu-Guard®
SMD Thin-Film Fuse
ACCU-GUARD® TECHNOLOGY
APPLICATIONS
The Accu-Guard® series of fuses is based on thin-film tech-
niques. This technology provides a level of control on the com-
ponent electrical and physical characteristics that is generally
not possible with standard fuse technologies. This has allowed
AVX to offer a series of devices which are designed for mod-
ern surface mount circuit boards which require protection.
• Cellular Telephones
• Two-Way Radios
• Computers
Not RoHS Compliant
• Battery Chargers
• Rechargeable Battery Packs
• Hard Disk Drives
• PDA’s
FEATURES
• Accurate current rating
• LCD Screens
For RoHS compliant products,
please select correct termination style.
• Fast acting
• SCSI Interface
• Digital Cameras
• Video Cameras
• Small-standard 0402, 0603, 0805, 1206 and 0612
chip sizes
• Taped and reeled
• Completely compatible with all soldering systems
used for SMT
APPROVAL FILE NUMBERS
• UL, cUL:
RCD#E143842
• Lead Free Series (F0402E, F02402G, F0603E, F0805B,
F1206B)
DIMENSIONS millimeters (inches)
F0603C, F0805B, F1206A and F1206B
F0402E and F0603E
F0402G
B1
B
S
A
B
H
T
T
T
W
B
L
L
L
W
F0402G
F0402E
F0603E
F0603C
F0805B
F1206A/B
F0612D
1.65 0.25
1.00 0.05
1.00 0.10
1.60 0.10
1.65 0.25
2.1 0.2
3.1 0.2
L
W
T
(0.039 0.002) (0.039 0.004) (0.063 0.004) (0.065 0.010) (0.083 0.008) (0.122 0.008) (0.065 0.010)
0.58 0.04
(0.023 0.002) (0.022 0.003) (0.032 0.004) (0.031 0.006) (0.050 0.004) (0.063 0.004) (0.122 0.008)
0.35 0.05 0.40 0.10 0.63 0.10 0.ꢀ0 0.15 0.90 0.2 1.2 0.2 0.90 0.2
(0.014 0.002) (0.016 0.004) (0.025 0.004) (0.028 0.006) (0.035 0.008) (0.04ꢀ 0.008) (0.036 0.008)
0.55 0.0ꢀ
0.81 0.10
0.80 0.15
1.2ꢀ 0.1
1.6 0.1
3.1 0.2
0.48 0.05
0.20 0.10
0.35 0.15
0.35 0.15
0.30 0.15
0.43 0.25
0.35 0.15
B
(0.019 0.002) (0.008 0.004) (0.014 0.006) (0.014 0.006) (0.012 0.006) (0.01ꢀ 0.010) (0.014 0.006)
0.20 0.05
(0.008 0.002)
0.05 0.05
A
S, H
(0.002 0.002)
HOW TO ORDER
F
1206
A
0R20
F
W
TR
Product
Size
See table for
standard sizes
Fuse Version
Rated Current
Current expressed in
Amps. Letter R denotes
decimal point. e.g.
0.20A=0R20
Fuse
Speed
F=Fast
Termination
S=Nickel/Lead-Free
Solder coated
(Sn 100)
W=Nickel/solder coated
(Sn 63, Pb 3ꢀ)
Packaging
TR=Tape and reel
Fuse
A=Accu-Guard®
B=Accu-Guard® II
C=Accu-Guard® II 0603
D=Accu-Guard® II 0612
E=Accu-Guard® II 0402, 0603
G=Accu-Guard® II 0402
Low Current
1.ꢀ5A=1Rꢀ5
N=Nickel/Lead-Free
Solder Coated (Sn100)
2
Accu-Guard® II Low Current
Miniature 0402 Size Thin-Film Fuses
The new F0402G Accu-Guard® series of fuses is based on
thin-film technology which allows precise control of the
component electrical and physical characteristics that is not
possible with standard fuse technologies. The Accu-Guard
Low Current series encompasses the lowest current ratings
in a compact 0402 package and features LGA terminations.
ELECTRICAL SPECIFICATIONS
Operating temperature: -55ºC to +125ºC
RECOMMEND PAD LAYOUT
millimeters (inches)
Current carrying capacity:
-55ºC to -11ºC 10ꢀ% of rating
-10ºC to +60ºC 100% of rating
+61ºC to +100°C 85% of rating
+101ºC to +125°C 80% of rating
0.55
(0.022)
Rated voltage: 32V
Post-fusing resistance: >1MΩ
0.31 (0.012)
1.15 (0.045)
Current
Rating
A
0.050
0.062
0.0ꢀ5
0.100
0.125
0.150
0.200
Resistance
@0.1 x IRATED
Ω (max.)
3.4
Voltage Drop
Fusing Current
(within 5 sec)
A
Pre-Arc I2t
@10xIRATED
A2-sec (typ)
2 x 10-6
Color
Code
Part Number
@IRATED
mV (max.)
250
F0402G0R05FNTR
F0402G0R06FNTR
F0402G0R0ꢀFNTR
F0402G0R10FNTR
F0402G0R12FNTR
F0402G0R15FNTR
F0402G0R20FNTR
0.125
0.155
0.18ꢀ5
0.250
0.312
0.3ꢀ5
0.500
Blue
Yellow
Brown
Red
White
Green
Pink
2.5
2.0
2.4
1.6
1.2
0.8
280
280
300
250
220
210
2 x 10-6
4 x 10-6
ꢀ x 10-6
1 x 10-5
2 x 10-5
4 x 10-5
ENVIRONMENTAL CHARACTERISTICS
Test
Conditions
Requirement
Solderability
Components completely immersed in a
solder bath at 245 5°C for 3 secs.
Components completely immersed in a solder
bath at 255 5°C for 60 secs.
12 months minimum with components
stored in “as received” packaging.
Components mounted to a substrate.
Increasing shearing force applied paralled to
the sufstrate till destruction.
Total area of imperfections in solder coating
up to 5% of the land suface area
Dissolution of termination
≤ 15% of the land surface area
Good solderability
Leach Resistance
Storage
Shear
Destruction at 5N force minimum
Temperature
Cycling
Bend
Components mounted to a flexible substrate
(e.g. FR – 4). 1000 cycles -55ºC to +125ºC.
Tested as shown in diagram
No Visible damage
ΔR/R<10%
No visible damage
ΔR/R<10%
3 mm
Deflection
45mm
45mm
Accu-Guard® II Low Current
Miniature 0402 Size Thin-Film Fuses
FUSE TIME – CURRENT CHARACTERISTICS
10
200 mA
150 mA
125 mA
1
10-1
10-2
10-3
10-4
100 mA
75 mA
62 mA
50 mA
10-5
10-6
0.1
1
10
Current, Amp
4
Accu-Guard® II Low Current
Miniature 0402 Size Thin-Film Fuses
FUSE PRE-ARC JOULE INTEGRALS VS CURRENT
10
1
200 mA
150 mA
125 mA
10-1
10-2
10-3
10-4
10-5
10-6
100 mA
75 mA
62 mA
50 mA
0
0.5
1
1.5
2
2.5
3
Current, Amp
Accu-Guard® II Low Current
Miniature 0402 Size Thin-Film Fuses
FUSE PRE-ARC JOULE INTEGRALS VS PRE-ARC TIME
10
1
200 mA 150 mA 125 mA
100 mA 75 mA
10-1
10-2
10-3
10-4
10-5
10-6
50 mA
62 mA
10-6
10-5
10-4
10-3
10-2
10-1
1
10
Pre-Arc Time, seconds
6
Accu-Guard® II
SMD Thin-Film Fuse
Accu-Guard® II is a version of Accu-Guard® fuses for a
wider range of current and voltage ratings. Constructed on
alumina substrates, Accu-Guard® II fuses display superior
electrical, mechanical and environmental properties.
Accu-Guard® II dimensions are standard 0402, 0603,
0805, 1206 and 0612 chip sizes, see page 2.
For F1206B and F0805B at -55°C is 10ꢀ% of rating, at
+25°C 100% of rating, at +85°C 93% of rating, at +125°C
90% of rating. For F0805B 2.50A and 3.00A at +85°C 90%
of rating, at +125°C 90% of rating.
Interrupting rating: 50A.
Insulation resistance: >20MΩ guaranteed (after fusing at
rated voltage).
ELECTRICAL SPECIFICATIONS
Operating temperature: -55°C to +125°C
For F0612D at -55°C 10ꢀ% of rating, at +25°C 100% of
rating, at +85°C 80% of rating, at +125°C ꢀ5% of rating.
Current carrying capacity:
For F0402E and F0603E at -55°C 10ꢀ% of rating, at -25°C
100% of rating, at +125°C 80% of rating. For F0603C at
-55°C is 10ꢀ% of rating, at +25°C 100% of rating, at +85°C
90% of rating, at +125°C ꢀ5% of rating.
Current
Resistance
Voltage Drop
Fusing Current
Pre-Arc
Rated
Type
Part Number
Rating 10% x I rated, 25°C @1 x I rated, 25°C (within 5 sec), 25°C
A
I2t @ 50A Voltage
Ω (max.)
0.650
0.250
0.200
0.130
0.060
0.040
0.650
0.450
0.250
0.200
0.130
0.090
0.060
0.050
0.040
0.035
0.030
0.800
0.500
0.320
0.300
0.200
0.1ꢀ0
0.110
0.090
0.0ꢀ5
0.055
0.045
0.ꢀ50
0.350
0.2ꢀ0
0.220
0.1ꢀ0
0.120
0.080
0.060
0.050
0.ꢀ50
0.350
0.180
0.120
0.080
0.050
0.040
0.025
mV (max.)
220
180
180
160
140
120
220
220
180
180
160
140
140
120
120
100
100
280
280
280
280
240
240
240
240
240
200
200
280
280
280
280
280
240
220
220
220
280
280
240
240
220
220
260
200
A
A2-sec
0.00005*
0.0003
0.003
0.008
0.03
V
F0402E0R25FSTR
F0402E0R50FSTR
F0402E0Rꢀ5FSTR
F0402E1R00FSTR
F0402E1R50FSTR
F0402E2R00FSTR
F0603E0R25FSTR
F0603E0R3ꢀFSTR
F0603E0R50FSTR
F0603E0Rꢀ5FSTR
F0603E1R00FSTR
F0603E1R25FSTR
F0603E1R50FSTR
F0603E1Rꢀ5FSTR
F0603E2R00FSTR
F0603E2R50FSTR
F0603E3R00FSTR
F0603C0R25FWTR
F0603C0R3ꢀFWTR
F0603C0R50FWTR
F0603C0Rꢀ5FWTR
F0603C1R00FWTR
F0603C1R25FWTR
F0603C1R50FWTR
F0603C1Rꢀ5FWTR
F0603C2R00FWTR
F0603C2R50FWTR
F0603C3R00FWTR
F0805B0R25FW/STR
F0805B0R50FW/STR
F0805B0Rꢀ5FW/STR
F0805B1R00FW/STR
F0805B1R25FW/STR
F0805B1R50FW/STR
F0805B2R00FW/STR
F0805B2R50FW/STR
F0805B3R00FW/STR
F1206B0R25FW/STR
F1206B0R50FW/STR
F1206B1R00FW/STR
F1206B1R50FW/STR
F1206B2R00FW/STR
F1206B3R00FW/STR
F0612D4R00FWTR
F0612D5R00FWTR
0.25
0.50
0.ꢀ5
1.00
1.50
2.00
0.25
0.3ꢀ5
0.50
0.ꢀ5
1.00
1.25
1.50
1.ꢀ5
2.00
2.50
3.00
0.25
0.3ꢀ5
0.50
0.ꢀ5
1.00
1.25
1.50
1.ꢀ5
2.00
2.50
3.00
0.25
0.50
0.ꢀ5
1.00
1.25
1.50
2.00
2.50
3.00
0.25
0.50
1.00
1.50
2.00
3.00
4.00
5.00
0.625
1.25
1.8ꢀ5
2.50
3.ꢀ5
5.00
0.625
0.940
1.25
1.8ꢀ5
2.50
3.125
3.ꢀ5
4.3ꢀ5
5.00
6.25
ꢀ.50
0.50
0.ꢀ5
1.00
1.50
2.00
2.50
3.00
3.50
4.00
5.00
6.00
0.50
1.00
1.50
2.00
2.50
3.00
4.00
5.00
6.00
0.50
1.00
2.00
3.00
4.00
6.00
10
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
24
24
16
16
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
32
32
F0402E
0.06
0.00005*
0.0001
0.0003
0.003
0.008
0.01
0.03
0.04
0.06
0.12
F0603E
0.25
0.00003*
0.0001
0.0002
0.0015
0.004
0.00ꢀ
0.012
0.02
F0603C
0.03
0.05
0.1
0.00003*
0.0002
0.001
0.003
0.00ꢀ
0.010
0.030
0.050
0.10
0.00003
0.0002
0.003
0.010
0.030
0.10
F0805B
F1206B
F0612D
0.10
0.25
12.5
*Current is limited to less than 50A at 32V due to internal fuse resistance.
Accu-Guard® II
SMD Thin-Film Fuse
ENVIRONMENTAL CHARACTERISTICS
Test
Solderability
Conditions
Requirement
Terminations to be well tinned
No visible damage
Dissolution of termination
≤ 25% of area
Components completely immersed in a
solder bath at 235 5°C for 2 secs.
Completely immersed in a solder bath
at 260 5°C for 60 secs.
Leach Resistance
ΔR/R<10%
Storage
Shear
12 months minimum with components
stored in “as received” packaging.
Components mounted to a substrate.
A force of 5N applied normal to the
line joining the terminations and in
a line parallel to the substrate.
Components mounted to a substrate.
50 cycles -55°C to +125°C.
Per Mil-Std-202F
Good solderability
No visible damage
Rapid Change of
Temperature
Vibration
No visible damage
Δ R/R<10%
No visible damage
ΔR/R<10%
Method 201A and
Method 204D Condition D.
Bend
Tested as shown in diagram
No visible damage
ΔR/R<10%
3 mm
Deflection
45mm
45mm
Load Life
F0805B, F1206B
25°C, rated current, 20,000 hrs.
No visible damage
ΔR/R<10%
8
Accu-Guard® II
Lead-Free SMD Thin-Film Fuse
FUSE TIME – CURRENT CHARACTERISTICS
FOR TYPE F0402E (TYPICAL)
10
1
2.0A
1.5A
10-1
1.0A
Pre-
Arc
Time,
0.75A
10-2
sec
0.5A
0.25A
10-3
10-4
10-5
10-6
0.1
1
10
100
Current, Amp
Accu-Guard® II
Lead-Free SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS VS CURRENT
FOR TYPE F0402E (TYPICAL)
100
10
1
10-1
Pre-
Arc
2.0A
1.5A
I2t,
10-2
10-3
10-4
10-5
10-6
A2sec
1.0A
0.75A
0.5A
0.25A
0
10
20
30
40
50
60
Current, Amp
10
Accu-Guard® II
Lead-Free SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS VS PRE-ARC TIME
FOR TYPE F0402E (TYPICAL)
100
100
0
10
1
0
10-1
Pre-
Arc I2t,
2.0A
1.5A
0
10-2
10-3
A2sec
0
1.0A
0
10-4
0.75A
0.5A
0
10-5
10-6
0.25A
0
0
0
0
0
0
0
0
10-6
10-5
10-4
10-3
10-2
10-1
1
10
Pre-Arc Time, sec
Accu-Guard® II
Lead-Free SMD Thin-Film Fuse
FUSE TIME – CURRENT CHARACTERISTICS
FOR TYPE F0603E (TYPICAL)
10
1
3.0A
2.5A
2.0A
1.75A
1.5A
10-1
1.25A
1.0A
10-2
0.75A
Pre-
Arc
Time,
sec
0.5A
0.375A
0.25A
10-3
10-4
10-5
10-6
0.1
1
10
100
Current, Amp
12
Accu-Guard® II
Lead-Free SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS VS CURRENT
FOR TYPE F0603E (TYPICAL)
100
10
3.0A
2.5A
2.0A
1.75A
1
10-1
10-2
10-3
10-4
10-5
10-6
1.5A
1.25A
1.0A
0.75A
0.5A
0.375A
0.25A
0
10
20
30
40
50
60
Current, Amp
Accu-Guard® II
Lead-Free SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS VS PRE-ARC TIME
FOR TYPE F0603E (TYPICAL)
100
3.0A
10
1
2.5A
2.0A
1.75A
1.5A
10-1
1.25A
1.0A
Pre-
10-2
10-3
10-4
10-5
10-6
Arc I2t,
A2sec
0.75A
0.5A
0.375A
0.25A
10-6
10-5
10-4
10-3
10-2
10-1
1
10
Pre-Arc Time, sec
14
Accu-Guard® II
SMD Thin-Film Fuse
FUSE TIME - CURRENT CHARACTERISTICS
FOR TYPE F0603C (TYPICAL)
10
1
0.15A
0.25A
0.375A
0.50A
0.75A
1.00A
1.25A
1.5A
1.75A
2.0A
2.5A
3.0A
10-1
10-2
10-3
10-4
10-5
10-6
0.1
1
10
100
Current, Amp
Accu-Guard® II
SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS
VS. CURRENT FOR TYPE F0603C (TYPICAL)
100
10
1
10-1
10-2
3.00A
2.50A
2.00A
1.75A
1.50A
1.25A
1.00A
0.75A
0.50A
0.375A
0.25A
0.15A
10-3
10-4
10-5
10-6
0
10
20
30
40
50
60
Current, Amp
16
Accu-Guard® II
SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS
VS. PRE-ARC TIME FOR TYPE F0603C (TYPICAL)
100
10
1
10-1
10-2
10-3
10-4
3.00A
2.50A
2.00A
1.75A
1.50A
1.25A
1.00A
0.75A
0.50A
0.375A
0.25A
0.15A
10-5
10-6
10-7
10-6
10-5
10-4
10-3
10-2
10-1
1
10
Pre-Arc Time, Seconds
Accu-Guard® II
SMD Thin-Film Fuse
FUSE TIME - CURRENT CHARACTERISTICS
FOR TYPES F0805B AND F1206B (TYPICAL)
10
1
0.15A
0.25A
0.50A
0.75A
1.00A
1.25A
1.5A
2.0A
2.5A
3.0A
10-1
10-2
10-3
10-4
10-5
10-6
0.1
1
10
100
Current, Amp
18
Accu-Guard® II
SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS
VS. CURRENT TIME FOR TYPES F0805B AND F1206B (TYPICAL)
100
10
1
10-1
10-2
3.00A
2.50A
2.00A
1.50A
1.25A
1.00A
0.75A
0.50A
10-3
10-4
10-5
10-6
0.25A
0.15A
0
10
20
30
40
50
60
Current, Amp
Accu-Guard® II
SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS
VS. PRE-ARC TIME FOR TYPES F0805B AND F1206B (TYPICAL)
100
10
1
10-1
10-2
10-3
10-4
3.00A
2.50A
2.00A
1.50A
1.25A
1.00A
0.75A
0.50A
0.25A
10-5
10-6
0.15A
10-7
10-6
10-5
10-4
10-3
10-2
10-1
1
10
Pre-Arc Time, Seconds
20
Accu-Guard® II
SMD Thin-Film Fuse
FUSE TIME - CURRENT CHARACTERISTICS
FOR TYPE F0612D (TYPICAL)
10
1
10-1
10-2
10-3
10-4
10-5
5.0A
4.0A
1
10
100
Current, Amp
Accu-Guard® II
SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS
VS. PRE-ARC TIME FOR TYPE F0612D (TYPICAL)
1000
100
10
1
5.00A
10-1
4.00A
10-2
10-3
10-4
10-5
10-6
10-5
10-4
10-3
10-2
10-1
1
10
Pre-Arc Time, Seconds
22
Accu-Guard® II
SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS
VS. CURRENT FOR TYPE F0612D (TYPICAL)
1000
100
10
1
5.00A
4.00A
10-1
10-2
10-3
10-4
10-5
0
10
20
30
Current, Amp
40
50
60
Accu-Guard®
SMD Thin-Film Fuse
ELECTRICAL SPECIFICATIONS
Operating Temperature: -55°C to +125°C
Current carrying capacity at -55°C is 10ꢀ% of rating;
at +25°C 100% of rating; at +85°C 93% of rating;
at +125°C 90% of rating.
Rated Voltage: 32V
Interrupting Rating: 50A
Insulation Resistance: >20MΩ guaranteed (after fusing at rated voltage)
1206
Current
Resistance
Voltage Drop
Fusing Current
Pre-Arc
Part Number
Rating @ 10% x I rated, 25°C @ 1 x I rated, 25°C (within 5 sec.) 25°C
I2 t @ 50A
A
Ω (Max.)
0.95
0.ꢀ5
0.40
0.35
0.25
0.18
0.15
0.11
mV (Max.)
350
A
A2 - sec.
F1206A0R20FWTR
F1206A0R25FWTR
F1206A0R3ꢀFWTR
F1206A0R50FWTR
F1206A0Rꢀ5FWTR
F1206A1R00FWTR
F1206A1R25FWTR
F1206A1R50FWTR
F1206A1Rꢀ5FWTR
F1206A2R00FWTR
0.200
0.250
0.3ꢀ5
0.500
0.ꢀ50
1.000
1.250
1.500
1.ꢀ50
2.000
0.40
0.50
0.ꢀ5
1.00
1.50
2.00
2.50
3.00
3.50
4.00
0.00002*
0.00004*
0.00006
0.0002
0.003
0.005
0.009
0.02
0.035
280
220
220
220
220
220
220
210
0.10
0.065
160
0.04
* Current is limited to less than 50A at 32V due to internal fuse resistance.
ENVIRONMENTAL CHARACTERISTICS
Test
Conditions
Requirement
Solderability
Components completely immersed in a
solder bath at 235 5°C for 2 secs.
Completely immersed in a solder bath
at 260 5°C for 60 secs.
Terminations to be well tinned
No visible damage
Dissolution of termination
≤ 25% of area
Leach Resistance
ΔR/R<10%
Storage
Shear
12 months minimum with components
stored in “as received” packaging.
Components mounted to a substrate.
A force of 5N applied normal to the
line joining the terminations and in
a line parallel to the substrate.
Components mounted to a substrate.
5 cycles -55°C to +125°C.
Good solderability
No visible damage
Rapid Change of
Temperature
Vibration
No visible damage
Δ R/R<10%
No visible damage
ΔR/R<10%
Per Mil-Std-202F
Method 201A and
Method 204D Condition D.
Load Life
25°C, I rated, 20,000 hrs.
No visible damage
ΔR/R<10%
24
Accu-Guard®
SMD Thin-Film Fuse
FUSE TIME - CURRENT CHARACTERISTICS
FOR SIZE 1206 (TYPICAL)
10
0.20A
0.25A
0.375A
0.50A
0.75A
1.00A
1.25A
1.50A
1.75A
2.00A
1
10-1
10-2
10-3
10-4
10-5
10-6
0.1
1
10
100
Current, Amp
Accu-Guard®
SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS VS. CURRENT
FOR SIZE 1206 (TYPICAL)
100
10
2.00A
1.75A
1
1.50A
1.25A
1.00A
10-1
10-2
10-3
0.75A
10-4
10-5
0.50A
0.375A
0.25A
0.20A
40
50
60
0
10
20
30
Current, Amp
26
Accu-Guard®
SMD Thin-Film Fuse
FUSE PRE-ARC JOULE INTEGRALS
VS. PRE-ARC TIME FOR SIZE 1206 (TYPICAL)
100
10
1
10-1
10-2
10-3
10-4
2.00A
1.75A
1.50A
1.25A
1.00A
0.75A
0.50A
0.375A
0.25A
0.20A
10-5
10-7
10-6
10-5
10-4
10-3
10-2
10-1
1
10
Pre-Arc Time, Seconds
Accu-Guard®
SMD Thin-Film Fuse
QUALITY & RELIABILITY
COMPONENT PAD DESIGN
Component pads must be designed to achieve good joints
and minimize component movement during soldering.
Accu-Guard® series of fuses is based on established
thin-film technology and materials used in the semiconduc-
tor industry.
Pad designs are given below for both wave and reflow
soldering.
• In-line Process Control: This program forms an integral
part of the production cycle and acts as a feedback sys-
tem to regulate and control production processes. The
test procedures, which are integrated into the production
process, were developed after long research and are
based on the highly developed semiconductor industry
test procedures and equipment. These measures help
AVX/Kyocera to produce a consistent and high yield line
of products.
The basis of these designs are:
a. Pad width equal to component width. It is permissible to
decrease this to as low as 85% of component width but
it is not advisable to go below this.
b. Pad overlap 0.5mm.
c. Pad extension 0.5mm for reflow. Pad extension about
1.0mm for wave soldering.
• Final Quality Inspection: Finished parts are tested for
standard electrical parameters and visual/mechanical
characteristics. Each production lot is 100% evaluated for
electrical resistance. In addition, each production lot is
evaluated on a sample basis for:
PREHEAT & SOLDERING
The rate of preheat in production should not exceed
4°C/second. It is recommended not to exceed 2°C/
second.
Temperature differential from preheat to soldering should
not exceed 150°C.
• Insulation resistance (post fusing)
• Blow time for 2 x rated current
• Endurance test: 125°C, rated current, 4 hours
For further specific application or process advice, please
consult AVX.
HANDLING AND SOLDERING
HAND SOLDERING & REWORK
SMD chips should be handled with care to avoid damage
or contamination from perspiration and skin oils. The use
of plastic tipped tweezers or vacuum pick-ups is strongly
recommended for individual components. Bulk handling
should ensure that abrasion and mechanical shock are
minimized. For automatic equipment, taped and reeled
product is the ideal medium for direct presentation to the
placement machine.
Hand soldering is permissible. Preheat of the PCB to 100°C
is required. The most preferable technique is to use hot air
soldering tools. Where a soldering iron is used, a tempera-
ture controlled model not exceeding 30 watts should be
used and set to not more than 260°C. Maximum allowed
time at temperature is 1 minute.
COOLING
CIRCUIT BOARD TYPE
All flexible types of circuit boards may be used
(e.g. FR-4, G-10).
After soldering, the assembly should preferably be allowed
to cool naturally. In the event of assisted cooling, similar
conditions to those recommended for preheating should
be used.
For other circuit board materials, please consult factory.
REFLOW SOLDERING
WAVE SOLDERING
Dimensions: millimeters (inches)
Dimensions: millimeters (inches)
0.8
0.85
(0.033)
0402
0805
0603
0402
0603
(0.031)
0.6
(0.024)
0805
1.0
(0.039)
1.25
(0.049)
2.1
(0.083)
1.5
0.5
(0.020)
(0.059)
2.3
(0.091)
0.6
(0.024)
1.7
(0.068)
3.0
0.5
(0.020)
(0.118)
3.1
(0.122)
0.6
(0.024)
1.0
0.8
(0.031)
4.0
(0.157)
(0.039)
0.85
1.0
(0.039)
(0.033)
0.6
(0.024)
0.59
(0.023)
1.25
(0.049)
1.0
(0.039)
0.8
(0.031)
0.59
(0.023)
1.5
(0.059)
1.25
(0.049)
0.8
(0.031)
1206
1.25
1.0
1206
(0.049)
0.85
(0.039)
0612
1.5
(0.033)
(0.059)
2.3
(0.091)
0.6 (0.024)
1.25
(0.049)
0612
4.0
(0.157)
0.85
(0.033)
5.0
(0.197)
2.0
(0.079)
3.1
0.6 (0.024)
2.0
(0.079)
3.1
(0.122)
(0.122)
1.25
(0.049)
3.1
(0.122)
1.0
(0.039)
1.5
(0.059)
1.6
(0.063)
1.6
(0.063)
28
Accu-Guard®
SMD Thin-Film Fuse
RECOMMENDED SOLDERING PROFILES
CLEANING RECOMMENDATIONS
Care should be taken to ensure that the devices are thor-
oughly cleaned of flux residues, especially the space
beneath the device. Such residues may otherwise become
conductive and effectively offer a lousy bypass to the
device. Various recommended cleaning conditions (which
must be optimized for the flux system being used) are as
follows:
IR REFLOW
220
Assembly exits heat–
210
200
190
180
170
160
150
140
130
120
110
100
90
no forced cooldown
Additional soak time
to allow uniform
heating of the
substrate
186°C solder melting
temperature
Assembly enters the
preheat zone
45-60 sec.
above solder
melting point
Cleaning liquids . . . . . . . .i-propanol, ethanol, acetylace-
tone, water, and other stan-
dard PCB cleaning liquids.
Ultrasonic conditions . . . .power – 20w/liter max. fre-
quency – 20kHz to 45kHz.
Soak time
80
1) Activates the flux
2) Allows center of board
temperatures to catch up with
corners
70
60
Temperature . . . . . . . . . .80°C maximum (if not other-
wise limited by chosen solvent
system).
50
40
30
20
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
Time . . . . . . . . . . . . . . . .5 minutes max.
Time (mins)
STORAGE CONDITIONS
Recommended storage conditions for Accu-Guard®
prior to use are as follows:
Temperature
Humidity
15°C to 35°C
≤65%
WAVE SOLDERING
Air Pressure
860mbar to 1060mbar
3–5 seconds
260
240
220
200
100°C
Natural
Cooling
180
160
140
120
100
80
Enter Wave
60
40
Time (seconds)
20
0
10
20
30
40
50
60
70
80
90 100 110 120
Transfer from
VAPOR PHASE
preheat with
min. delay &
temp. loss
Preheat
Reflow
215°C
215°C
200
180
160
140
120
100
80
200
Duration varies
with thermal mass
of assembly
Natural
Cooling
180
160
140
120
100
80
10–60 secs typical
Enter
Vapor
60
60
40
40
20
20
0
0
10
20
30
40
50
60
70
Time (minutes)
Time (seconds)
Accu-Guard®
SMD Thin-Film Fuse
PACKAGING
Automatic Insertion Packaging
Tape & Reel: All tape and reel specifications are in compliance with EIA 481-1
— 8mm carrier
— Reeled quantities: Reels of 3,000 or 10,000 pieces
(for F0402: 5,000 or 20,000 pieces)
G MAX.
B*
C
A
E
D*
FULL RADIUS
F
*DRIVE SPOKES OPTIONAL
IF USED, ASTERISKED
DIMENSIONS APPLY.
REEL DIMENSIONS: millimeters (inches)
A(1)
B*
C
D*
E
F
G
180 + 1.0
(ꢀ.08ꢀ + 0.039) (0.059 min.)
1.5 min.
13 0.2
(0.512 0.008)
20.2 min.
(0.ꢀ95 min.)
50 min.
(1.969 min.)
9.4 1.5
(0.3ꢀ0 0.050)
14.4 max.
(0.56ꢀ max.)
Metric dimensions will govern.
Inch measurements rounded for reference only.
(1) 330mm (13 inch) reels are available.
10 PITCHES
CUMULATIVE
TOLERANCE ON
TAPE 0.2
E
D
F
C
TOP
TAPE
W
L
B
A
CENTER LINES
OF CAVITY
DIRECTION OF FEED
P = 4mm except 0402 where P = 2mm
CARRIER DIMENSIONS: millimeters (inches)
A
B
C
D
E
F
+0.1
8.0 0.3
(0.315 0.012)
3.5 0.05
(0.138 0.002)
1.ꢀ5 0.1
(0.069 0.004)
2.0 0.05
(0.0ꢀ9 0.002)
4.0 0.1
(0.15ꢀ 0.004)
1.5
(0.059
-0.0
+0.004
)
-0.000
Note: The nominal dimensions of the component compartment (W,L) are derived from the component size.
Note: AVX reserves the right to change the information published herein without notice.
30
Accu-Guard®
SMD Thin-Film Fuse
HOW TO CHOOSE THE CORRECT ACCU-GUARD® FUSE
FOR CIRCUIT PROTECTION
Correct choice of an Accu-Guard® fuse for a given applica-
tion is fairly straightforward. The factor of pre-arc I2t, howev-
er, requires clarification. The proper design for pre-arc I2t is
presented by way of example.
5. Switch-on and Other Pulse Current
Many circuits generate a large current pulse when initially
connected to power. There are also circuits which are sub-
ject to momentary current pulses due to external sources;
telephone line cards which are subject to lightning-induced
pulses are one example. These current pulses must be
passed by the fuse without causing actuation. These puls-
es may be so large that they are the determining factor for
choosing the Accu-Guard® current rating; not necessarily
steady state current.
DESIGN PARAMETERS
1. Operating Temperature
The Accu-Guard® is specified for operation in the tempera-
ture range of -55°C to +125°C. Note, however, that fusing
current is sensitive to temperature. This means that the fuse
must be derated or uprated at circuit temperatures other
than 25°C:
In order to design for current pulses, the concept of fuse
pre-arc Joule integral, I2t, must be understood. Fuse current
rating is defined by the requirement that 2 x IR will cause
actuation in <5 seconds. This rating does not indicate how
the fuse will react to very high currents of very short duration.
Rather, the fusing characteristic at very high currents is
specified by I2t-t curves (or I2t-I).
I2t expresses the amount of energy required to actuate the
fuse. Total I2t expresses the total energy which will be
passed by the fuse until total cessation of current flow.
Pre-arc I2t expresses that energy required to cause large
irreversible damage to the fuse element (Total I2t = pre-arc I2t
+ arc I2t). If the Joule integral of the switch-on pulse is
larger than the fuse pre-arc I2t, nuisance actuation will occur.
Environmental
Temperature
Accu-Guard®
Current Carrying Capacity*
F0402E,
F0603E
F0805B, F1206A, F0805B 2.50A
F0603C F0612D
1.0ꢀ x IR 1.0ꢀ x IR
F1206B
1.0ꢀ x IR
IR
& 3.00A
1.0ꢀ x IR
IR
-55°C to -11°C
-10°C to 60°C
61°C to 100°C
101°C to 125°C
1.0ꢀ x IR
IR
IR
IR
0.85 x IR
0.80 x IR
0.93 x IR
0.90 x IR
0.90 x IR
0.90 x IR
0.90 x IR 0.80 x IR
0.ꢀ5 x IR 0.ꢀ5 x IR
*As a function of nominal rated current, IR.
In order to choose the proper Accu-Guard® current rating for
a given application, it is necessary to calculate the I2t Joule
integral of the circuit switch-on and other current pulses and
compare them to the Accu-Guard® I2t-t curves. An Accu-
Guard® fuse must be chosen such that the pulse I2t is no
more than 50% of the pre-arc I2t of the prospective fuse.
Pre-arc I2t of the Accu-Guard® fuses is well characterized;
I2t-t and I2t-I graphs are in this catalog. The problem is cal-
culating the I2t of the circuit current pulses. This concept is
not familiar to most engineers. Correct calculation of pulse
Joule integral and subsequent choice of Accu-Guard®
current rating is illustrated by way of the attached examples.
2. Circuit Voltage
Maximum Voltage: Accu-Guard® is specified for circuits of
up to rated voltage. Accu-Guard® will successfully break
currents at higher voltages as well, but over voltage may
crack the fuse body.
Minimum Voltage: Accu-Guard® cannot be used in circuits
with voltage of about 0.5V and less. The internal resistance
of the fuse will limit the fault current to a value which will pre-
vent reliable actuation of the fuse (<2 x rated current).
3. Maximum Fault Current
Accu-Guard® is fully tested and specified for fault currents
up to 50A. Accu-Guard® will successfully break currents
above 50A, but such over current may crack the fuse body
or damage the fuse terminations.
4. Steady-State Current
The Accu-Guard® current rating is based on IEC Specifica-
tion 12ꢀ-3. In accordance with this international standard,
Accu-Guard® is specified to operate at least 4 hours at rated
current without fusing (25°C). Engineering tests have shown
that F0805B and F1206A/B Accu-Guard® will in fact operate
at least 20,000 hours at rated current without fusing (25°C).
Accu-Guard®
SMD Thin-Film Fuse
2. Triangular current pulse
The Joule integral for triangular pulse is
[(Imax.)2 x t]/3,
DESIGNING FOR CURRENT
PULSE SITUATIONS
1. Sine wave current pulse
The Joule integral for sine wave pulse is
see Fig. 2a.
[(Imax.)2 x t]/2,
l max.
see Fig. 1a.
l max.
t
Fig. 2a. Triangular pulse parameters for Joule
t
integral calculation, example #2.
Fig. 1a. Sine wave pulse parameters for Joule
integral calculation, example #1.
Thus, for the current pulse in Figure 1b, the Joule integral is
[(4.8A)2 x ꢀ.ꢀ x 10-6 sec]/2 = 8.9 x 10-5 A2 sec.
Thus, for the current pulse in Figure 2b, the Joule integral is
[(1.5A)2 x 3 x 10-3 sec]/3 = 2.25 x 10-3 A2sec.
2 msec/div
10 μsec/div
0.5A/div
1A/div
Fig. 1b. Sine wave pulse, example #1.
Fig. 2b. Triangular pulse, example #2.
The pulse duration is 3 msec. In the I2t graph on page 6, pre-
arcing Joule integral for 3 msec pulse is 4 x 10-3A2sec for the
0.5A fuse (not enough) and 2 x 10-2 for the 0.ꢀ5A fuse (more
than enough). Therefore, 0.ꢀ5A fuse should be chosen for
this application, see Figure 2c.
The pulse duration is ꢀ.ꢀμsec. We must find a fuse that can
absorb at least 8.9 x 10-5 X 2 = 1.8 x 10-4 A2sec Joule inte-
gral within ꢀ.ꢀ μsec without actuation. According to the I2t
graph on page 6, pre-arcing Joule integral is 2.3x10-4 A2sec
for the 0.5A fuse, which is slightly more than needed. The
next lower rating (0.3ꢀ5A), has only 6x10-5 A2sec, which is
not enough. Therefore, 0.5A fuse should be chosen for this
application, see Figure 1c.
FUSE PRE-ARCING JOULE INTEGRALS
vs. PRE-ARCING TIME
PRE-ARCING TIME l2t, A2 sec
100
FUSE PRE-ARCING JOULE INTEGRALS
vs. PRE-ARCING TIME
10
1
10-1
PRE-ARCING TIME l2t, A2 sec
100
0.75A
10
1
10-2
10-3
x
10-4
10-5
10-1
10-2
0.5A
10-3
10-4
10-7 10-6 10-5 10-4 10-3 10-2 10-1
PRE-ARCING TIME, sec
1
10
x
Fig. 2c. Choice of 0.ꢀ5A fuse, example #2.
Pre-arcing I2t
10-5
10-7 10-6 10-5 10-4 10-3 10-2 10-1
PRE-ARCING TIME, sec
1
10
Maximum I2t design rule
Fig. 1c. Choice of 0.5A fuse, example #1.
X
I2t for sample switch-on pulse
Pre-arcing I2t
Maximum I2t design rule
I2t for sample current pulse
X
32
Accu-Guard®
SMD Thin-Film Fuse
DESIGNING FOR CURRENT PULSE SITUATIONS (CONT.)
3. Trapezoidal current pulse
4. Lightning strike
The Joule integral for a trapezoidal pulse is
A lightning strike pulse is shown in Figure 4a. After an initial
(Imin.)2 + Imin. x (Imax. - Imin.) + (Imax-Imin)2 x t,
linear rise, the current declines exponentially.
[
]
3
see Fig. 3a.
l max.
0.51 max.
t0.5
l max.
l min.
Fig. 4a. Lightning pulse parameters for Joule
t
integral calculation, example #4.
Fig. 3a. Trapezoidal pulse parameters for Joule
Joule integral for the linear current rise is calculated as for a
triangular pulse, see example #2.
integral calculation, example #3.
Thus, for current pulse in Figure 3b, the Joule integral is:
The Joule integral for the exponential decline is
Imax.2 x t0.5 x (-1/2In 0.5) = 0.ꢀ2Imax.2 x t0.5
{(0.56A)2+0.56A x (1A-0.56A)+ (1A-0.56A)2 } x 3 x 10-3s = 1.9 x 10-3A2sec.
[
]
3
Thus, for the sample lightning strike pulse in Figure 4b, the
total Joule integral is:
0.5 msec/div
(25A)2 x 2 x 10-6sec/3+0.ꢀ2 x (25A)2 x 10 x 10-6sec = 4.92 x 10-3A2sec.
10 μsec/div
0.5A/div
5A/div
Fig. 3b. Trapezoidal pulse, example #3.
According to the I2t graph on page 6, the 0.5A fuse should
be chosen for this application, see Figure 3c.
Fig. 4b. Lightning strike pulse, example #4.
For practical calculations, the duration of exponential decline
may be assumed to be 3t0.5, because within this time 98.5%
of the pulse energy is released. Thus, the total pulse duration
in this example is 30 μsec, and the 1.25A fuse should be
chosen for this application, see Figure 4c.
FUSE PRE-ARCING JOULE INTEGRALS
vs. PRE-ARCING TIME
PRE-ARCING TIME l2t, A2 sec
100
10
1
10-1
FUSE PRE-ARCING JOULE INTEGRALS
vs. PRE-ARCING TIME
PRE-ARCING TIME l2t, A2 sec
10-2
100
x
0.50A
10-3
10-4
10-5
10
1
10-1
1.25A
10-7 10-6 10-5 10-4 10-3 10-2 10-1
PRE-ARCING TIME, sec
1
10
10-2
x
10-3
10-4
10-5
Fig. 3c. Choice of 0.5A fuse, example #3.
Pre-arcing I2t
Maximum I2t design rule
10-7 10-6 10-5 10-4 10-3 10-2 10-1
PRE-ARCING TIME, sec
1
10
I2t for sample switch-on pulse
X
Fig. 4c. Choice of 0.5A fuse, example #4.
Pre-arcing I2t
Maximum I2t design rule
I2t for sample switch-on pulse
X
Accu-Guard®
SMD Thin-Film Fuse
DESIGNING FOR CURRENT PULSE SITUATIONS (CONT.)
5. Complex current pulse
6. Switch-on pulse and steady-state current
In Figure 6a, the switch-on pulse is a triangle pulse with a
5.1 x 10-3 A2sec Joule integral of 5 msec duration; the 0.ꢀ5A
fuse will meet this requirement, see Figure 6b.
If the pulse consists of several waveforms, all of them should
be evaluated separately, and then the total Joule integral
should be calculated as well.
200 μsec/div
2 msec/div
2A/div
0.5A/div
Fig. 5a. Complex pulse, example #5.
Fig. 6a. Switch-on pulse and steady-state current,
example #6.
In Figure 5a, the Joule integral for the first triangle is
[(4.6ꢀA)2 x 294 x 10-6sec]/3=2.14 x 10-3 A2sec
and 0.ꢀ5A fuse should meet this condition, see Figure 5b.
FUSE PRE-ARCING JOULE INTEGRALS
vs. PRE-ARCING TIME
PRE-ARCING TIME l2t, A2 sec
100
FUSE PRE-ARCING JOULE INTEGRALS
vs. PRE-ARCING TIME
PRE-ARCING TIME l2t, A2 sec
10
1
10-1
100
0.75A
10-2
10-3
10-4
10-5
x
10
1
10-1
0.75A
10-2
x
x
10-7 10-6 10-5 10-4 10-3 10-2 10-1
PRE-ARCING TIME, sec
1
10
10-3
10-4
10-5
Fig. 6b. Choice of 0.ꢀ5A fuse, example #6.
Pre-arcing I2t
10-7 10-6 10-5 10-4 10-3 10-2 10-1
PRE-ARCING TIME, sec
1
10
Maximum I2t design rule
I2t for sample switch-on pulse
Fig. 5b. Choice of fuse, example #5.
Pre-arcing I2t
X
Maximum I2t design rule
I2t for sample switch-on pulse
The steady-state current is 0.5A, and 1A fuse is typically rec-
ommended to meet the steady-state condition. Based on
steady-state current, the 1A fuse should be chosen for this
application.
X
The Joule integral for the second triangle is
[(5.33A)2 x 269 x 10-6sec]/3 = 2.55 x 10-3 A2sec, and
0.ꢀ5A fuse is suitable for this case also, see Figure 5b.
However, for the whole pulse, the Joule integral is
4.ꢀ x 10-3 A2sec, and the total duration is 563 μsec. For the
0.ꢀ5A fuse, the Joule integral is only 8.6 x 10-3 A2sec for this
pulse duration, so the 1A fuse should be chosen for this
application, see Figure 5b.
34
AVX Products Listing
PASSIVES
CONNECTORS
2mm Hard-Metric for CompactPCI®
Capacitors
Multilayer Ceramic
Tantalum
Filters
EMI
Automotive Connectors
Board to Board Connectors –
SMT and Through-Hole
Card Edge
Compression
Custom Designed Connectors
Customized Backpanel, Racking and
Harnessing Services
DIN 41612 Connectors
FFC/FPC Connectors
Insulation Displacement Connectors
I/O Connectors
Memory Card Connectors
CF, PCMCIA, SD, MMC
MOBOTM, I/O, Board to Board and
Battery Connectors
Press-fit Connectors
Varicon®
Wire to Board, Crimp or IDC
SAW
Dielectric
Microwave
Glass
Film
Power Film
Power Ceramic
Ceramic Disc
Trimmer
Thin Film
Inductors
Fuses
Capacitors
Couplers
Baluns
BestCap™
Filters
Resistors
Integrated Passive
Components
Arrays
Timing Devices
Resonators
Oscillators
Low Inductance Chip Arrays
Capacitor Arrays
Dual Resonance Chips
Custom IPCs
Crystals
Voltage Suppressors,
Varistors and Thermistors
Acoustical Piezos
For more information please visit
our website at
http://www.avx.com
Internet/FAX/CD Rom/Software
Need Additional Information on AVX Products
Internet –
For more information visit us on the worldwide web at
http://www.avx.com
CD ROM –
Or get in touch with your AVX representative for a CD Rom or copies
of the catalogs and technical papers.
Software –
Comprehensive capacitor application software library which includes:
SpiCap (for MLC chip capacitors)
SpiTan (for tantalum capacitors)
SpiCalci (for power supply capacitors)
SpiMic (for RF-Microwave capacitors)
36
AMERICAS
EUROPE
ASIA-PACIFIC
ASIA-KED
(KYOCERA Electronic Devices)
AVX Greenville, SC
Tel: 864-967-2150
AVX/Kyocera (S) Pte Ltd.,
Singapore
KED Hong Kong Ltd.
Tel: +852-2305-1080/1223
AVX Limited, England
Tel: +44-1276-697000
Tel: +65-6286-7555
AVX Northwest, WA
Tel: 360-699-8746
AVX S.A.S., France
Tel: +33-1-69-18-46-00
KED Hong Kong Ltd.
Shenzen
Tel: +86-755-3398-9600
AVX/Kyocera, Asia, Ltd.,
Hong Kong
AVX Midwest, IN
Tel: 317-861-9184
AVX GmbH, Germany
Tel: +49-0811-95949-0
Tel: +852-2363-3303
KED Company Ltd.
Shanghai
Tel: +86-21-3255-1833
AVX/Kyocera Yuhan Hoesa,
South Korea
AVX Mid/Pacific, CA
Tel: 408-988-4900
AVX SRL, Italy
Tel: +39-02-614-571
Tel: +82-2785-6504
KED Hong Kong Ltd.
Beijing
Tel: +86-10-5869-4655
AVX Northeast, MA
Tel: 617-479-0345
AVX/Kyocera HK Ltd.,
Taiwan
Tel: +886-2-2656-0258
AVX Czech Republic
Tel: +420-57-57-57-521
AVX/ELCO UK
Tel: +44-1638-675000
AVX Southwest, CA
Tel: 949-859-9509
KED Taiwan Ltd.
Tel: +886-2-2950-0268
AVX/Kyocera (M) Sdn Bhd,
Malaysia
Tel: +60-4228-1190
ELCO Europe GmbH
Tel: +49-2741-299-0
AVX Canada
Tel: 905-238-3151
KED Korea Yuhan
Hoesa, South Korea
AVX/Kyocera International
Trading Co. Ltd.,
Shanghai
Tel: +82-2-783-3604/6126
AVX South America
Tel: +55-11-4688-1960
AVX S.A., Spain
Tel: +34-91-63-97-197
KED (S) Pte Ltd.
Singapore
Tel: +86-21-3255 1933
AVX Benelux
Tel: +31-187-489-337
AVX/Kyocera Asia Ltd.,
Shenzen
Tel: +65-6509-0328
Kyocera Corporation
Japan
Tel: +81-75-604-3449
Tel: +86-755-3336-0615
AVX/Kyocera International
Trading Co. Ltd.,
Beijing
Tel: +86-10-6588-3528
AVX/Kyocera India
Liaison Office
Tel: +91-80-6450-0715
Contact:
A KYOCERA GROUP COMPANY
http://www.avx.com
S-ACCU5M612-C
相关型号:
F1206B1R00FSTR
Electric Fuse, Fast Blow, 1A, 32VAC, 32VDC, 50A (IR), Surface Mount, LEAD FREE
KYOCERA AVX
©2020 ICPDF网 联系我们和版权申明